TC 40 Series

TC 40 Series

Parameters

 

Qmax: 18 m3/h


Hmax: 10 m

 

Design

 

Submersible sewage pump

 

 

Application

 

Pumping of heavily contaminated fluids for:
  • House/site drainage
  • Sewage disposal (the pumping of sewage containing faeces is not within the scope of DIN EN 12050-1)
  • Water management
  • Environmental and water treatment technology

 

 

Type key

 

e.g.: Wilo-Drain TC 40/10
T Submersible pump
C Hydraulic housing made of cast iron
40 Nominal diameter [mm]
10 Max. delivery head [m]

 

 

Special features/product benefits

 

  • Heavy-duty hydraulic housing made of cast iron
  • Easy operation due to the attached float switch
  • Integrated stainless steel pump base for easy installation
  • Free ball passage: 40 mm

 

 

Technical data

 

  • Mains connection: 1~230 V, 50 Hz
  • Immersed operating mode: S1 or S3 25%
  • Surfaced operating mode: S3 25%
  • Protection class: IP 68
  • Insulation class: F
  • Thermal winding monitoring
  • Max. fluid temperature: 3 - 40 °C
  • Cable length: 5 m
  • Free ball passage: 40 mm
  • Max. immersion depth: 5 m

Equipment/function

 

  • Ready-to-plug
  • Including float switch
  • Thermal motor monitoring

 

 

Description/design

 

Submersible sewage pump as submersible monobloc unit for stationary and portable wet well installation.
Hydraulics
The outlet on the pressure side is designed as vertical threaded connection Rp 1½. Vortex impeller are used as the impeller shapes.
Motor
The oil-filled motors give off heat directly to the pumped fluid via an integrated heat exchanger. As a result, these motors can be used in immersed state for permanent and intermittent operation. In non-immersed state, these motors can be used for intermittent operation.
A sealing chamber protects the motor from fluid ingress. The filling fluid used is potentially biodegradable and environmentally safe.
The motor cable and float switch can be detached and replaced.
Sealing
Sealing on the fluid side is achieved by a bidirectional mechanical seal, while sealing on the motor side is achieved by a rotary shaft seal.

 

 

Materials

 

  • Pump housing: EN-GJL-200
  • Pedestal: stainless steel
  • Impeller: PA 30GF
  • Shaft: stainless steel 1.4005
  • Mechanical seal on pump side: carbon/ceramic
  • Shaft seal on motor side: NBR
  • Static gasket:NBR
  • Motor housing: stainless steel 1.4308

 

 

Scope of delivery

 

  • Pump ready for connection with 5 m connecting cable and shock-proof plug
  • With attached float switch
  • Installation and operating instructions

 

 

Accessories

 

  • Non-return valve and gate valve
  • Various pressure outlets and hoses
  • Switchgears and relays